MINMAX产品-MINMAX模块电源
1W, High Isolation SIP, Single & Dual Output DC/DC Converters | |
|
Key Features |
‧ Efficiency up to 81% |
‧ 3000VDC Isolation |
‧ MTBF > 2,000,000 Hours |
‧ Low Cost |
‧ Input 5, 12 and 24VDC |
‧ Output 3.3, 5, 9, 12, 15, ±5, ±9, ±12 and ±15VDC |
‧ Temperature Performance -40°C to +85°C |
‧ UL 94V-0 Package Material |
‧ Internal SMD Construction |
‧ Industry Standard Pinout | |
|
|
Model Number |
Input Voltage |
Output Voltage |
Output Current |
Efficiency |
Load Regulation |
VDC |
VDC |
mA |
% Typ. |
% Max. |
MAU201 |
|
3.3 |
260 |
73 |
10 |
MAU202 |
5 |
200 |
71 |
10 |
MAU203 |
9 |
110 |
76 |
8 |
MAU204 |
12 |
84 |
78 |
7 |
MAU205 |
15 |
67 |
78 |
7 |
MAU206 |
±5 |
±100 |
72 |
10 |
MAU207 |
±9 |
±56 |
77 |
8 |
MAU208 |
±12 |
±42 |
78 |
7 |
MAU209 |
±15 |
±34 |
79 |
7 |
MAU211 |
|
3.3 |
260 |
74 |
8 |
MAU212 |
5 |
200 |
73 |
8 |
MAU213 |
9 |
110 |
78 |
5 |
MAU214 |
12 |
84 |
80 |
5 |
MAU215 |
15 |
67 |
80 |
5 |
MAU216 |
±5 |
±100 |
74 |
8 |
MAU217 |
±9 |
±56 |
79 |
5 |
MAU218 |
±12 |
±42 |
81 |
5 |
MAU219 |
±15 |
±34 |
81 |
5 |
MAU221 |
|
3.3 |
260 |
73 |
8 |
MAU222 |
5 |
200 |
71 |
8 |
MAU223 |
9 |
110 |
76 |
5 |
MAU224 |
12 |
84 |
78 |
5 |
MAU225 |
15 |
67 |
79 |
5 |
MAU226 |
±5 |
±100 |
72 |
8 |
MAU227 |
±9 |
±56 |
76 |
5 |
MAU228 |
±12 |
±42 |
79 |
5 |
MAU229 |
±15 |
±34 |
80 |
5 | |
| |
|
Minmax's MAU200 1W DC/DC's are specially designed to provide high levels of isolation 3000VDC in a miniature SIP package.
The series consists of 27 models with input voltages of 5V, 12V and 24VDC which offers standard output voltages of 3.3V, 5V, 9V, 12V, 15V, ±5V, ±9V, ±12V and ±15VDC for a wide choice.
The MAU200 series is an excellent selection for a variety of applications including distributed power systems, mixed analog/digital subsystems, portable test equipments, local power networks and battery backed systems.
|
Mechanical Dimensions |
Pin Connections |
|
Pin |
Singles |
Duals |
1 |
+Vin |
+Vin |
2 |
-Vin |
-Vin |
5 |
-Vout |
-Vout |
6 |
No Pin |
Common |
7 |
+Vout |
+Vout |
Case Size – |
5V & 12V Input – 19.5x6.1x10.2mm |
|
(0.77x0.24x0.40inch)
|
24V Input –19.5x7.1x10.2mm |
|
(0.77x0.28x0.40inch)
|
Case Material – |
Non-Conductive Black Plastic |
Weight – |
5V & 12V Input – 2.2g (0.08Oz) |
24V Input– 2.6g (0.09Oz) |
Tolerance |
Millimeters |
Inches |
|
X.X±0.25 |
X.XX±0.01 |
|
X.XX±0.13 |
X.XXX±0.005 |
Pin |
±0.05 |
±0.002 |
| |
|
|
| |
|
Absolute Maximum Ratings |
Parameter |
Min. |
Max |
Units |
Input Surge Voltage (1000mS) |
5VDC Input Models |
-0.7 |
9 |
VDC |
12VDC Input Models |
-0.7 |
18 |
VDC |
24VDC Input Models |
-0.7 |
30 |
VDC |
Lead Temperature (1.5mm from case for 10sec.) |
--- |
260 |
°C |
Internal Power Dissipation |
--- |
450 |
mW | Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings. |
|
General Characteristics |
Parameter |
Conditions |
Min. |
Typ. |
Max. |
Units |
Isolation Voltage |
60 Seconds |
3000 |
--- |
--- |
VDC |
Isolation Resistance |
500VDC |
10 |
--- |
--- |
GΩ |
Isolation Capacitance |
100kHz, 1V |
--- |
60 |
100 |
pF |
Switching Frequency |
|
70 |
100 |
120 |
kHz |
MTBF |
MIL-HDBK-217F @25°C Ground Benign |
2 |
--- |
--- |
MHrs | | |
|
Environmental Characteristics |
Parameter |
Conditions |
Min. |
Max. |
Units |
Operating Temperature |
Ambient |
-40 |
+85 |
°C |
Operating Temperature |
Case |
-40 |
+90 |
°C |
Storage Temperature |
|
-40 |
+125 |
°C |
Humidity |
|
--- |
95 |
% |
Cooling |
Free-Air Convection | |
|
Output Characteristics |
Parameter |
Conditions |
Min. |
Typ. |
Max |
Units |
Line Regulation |
|
--- |
±1.2 |
±1.5 |
% |
Load Regulation |
Io = 20% to 100% |
See Selection Guide
|
% |
Ripple & Noise
|
20MHz BW |
--- |
65 |
100 |
mV P-P |
Short Circuit |
0.5 Second Max. | |
|
|
Maximum Capacitive Load |
Models by Output Voltage (Each Output on Duals) |
Singles |
Duals |
Units |
220 |
100 |
uF | |
| |
|
Derating Curve (3.3, 5 & ±5V Outputs) |
| |
|
|
1. |
Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. |
2. |
These power converters require a minimum output load to maintain specified regulation. |
3. |
Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. |
4. |
All DC/DC converters should be externally fused at the front end for protection. |
5. |
Other input and output voltage may be available, please contact factory |
6. |
All specifications subject to change without notice. |
|
| |
|
Derating Curve (Other Outputs) |
| |
|
| |