蓄电池在线内阻在直流电源系统中的监测技术及运用
作者:关大凯 上传时间:2010/4/7 15:13:56
摘要:通过分析直流电源系统中VRLA蓄电池运行状况和电池失效的常见现象,研究了蓄电池在线监测管理系统应解决的关键问题,主要包括:①监测管理系统的合理结构;②电池组及电池单体的电压、电流巡检与数据分析;③电池单体的内阻测量;④电池运行事件记录;⑤远程管理。文中结合BM-6500电池管理系统在直流电源系统的应用进行了相关论述,本系统提高了直流电源运行的可靠性。
叙词:蓄电池 监测 内阻测量 在线维护
Abstract:Basing on analyze to the run state and the phenomenon of runaway of VRLA battery used in DC power systems, the key technologies of the on-line battery internal resistance monitoring system have been studied. They are the reasonable structure; monitoring batteries and analyzing the data; internal resistance testing and alarming; running accident recording; remote management. Combining with the experience from developing the BM-6500 series of battery management systems, the related problems have been discussed in this paper. this system can promote the reliability of DC power sources which service in DCpower systems.
Keyword:VRLAB, Monitor, Internal resistance measurement, On-line maintenance
说明:本站会员正确输入用户名和密码进行登录系统后才能查看文章详细内容和参与评论。
--本文摘自《电源世界》,已被阅读2555次
免责声明:本文仅代表作者个人观点,与电源在线网无关。其原创性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不作任何保证或承诺,请读者仅作参考,并请自行核实相关内容。