蓄电池内阻及其同蓄电池各类失效模式的关系
作者:王秀菊 上传时间:2004/12/23 10:55:16
摘要:通过分析蓄电池运常见的现象电池失效模式和内阻的关系,研究了蓄电池在线监测管理系统应解决的关键问题,主要包括:1)监测管理系统的合理结构,2)电池单体的内阻数据在蓄电池监测系统的可靠性,3)内阻和剩余容量关系。文中结合电池管理系统在直流操作系统的应用进行了相关论述,本系统提高了直流电源运行的可靠性。
叙词:蓄电池 失效模式 内阻
Abstract:The paper studies the crux that the battery on-line monitor management system solve according to the analysis of the running battery, the relation between the model of abeyance and internal resistance. Including: 1) The reasonable structure of monitor .2) The reliability of the internal resistance data of single battery in the battery monitor system.3) The relation between internal resistance and the rest of capacity. The paper discusses the use of the battery management system in D.C operating system. The system improves the reliability of the running direct power supply.
Keyword:VRLAB, the model of abeyance, internal resistance