摘要:具备“冗余式”供电能力为3800KVA,其最大供电能力高达6000KVA的超大型IDC机房用智能化UPS供电系统采用的是“双总线输入”、“双总线输出”+“负载同步控制器”+“负载自动切换开关”设计方案所构成的、具有世界一流技术水平的超大型UPS供电系统。这种“端到端”的一体化UPS供电系统不仅可以消除各种可能出现的“单点瓶颈”故障隐患,而且还可向位于IDC机房内的各种IT设备连续提供365*24小时高品质的UPS逆变器电源。
叙词:超大型IDC机房 智能化UPS供电系统
Abstract:An intelligent ups system with redundant capability of 3800KVA and max.capability of 6000KVA for super large-scale IDC Room is designed and completed.It is composed of such as advanced technology of the input dual bus ,the output dual bus,the Load bus synchronization(LBS)and the Automatic static Transfer switch(STS) and so on.This IDC room is equipped with a super large-scale ups system of the first-rate world levels.Due to the adoption of the end-to-end integrated ups system with total solution scheme,it is not only favourable for removing a "bottleneck type"of the "simple-point"hidden danger and failure in the power supply system,but also it is favourable for supplying a variety of IT equipment in this IDC room with high quality of the continued UPS "inverter power supply"for 365*24Hrs.