移相全桥ZVS变换器整流桥寄生振荡的抑制
作者:皮之军 上传时间:2006/7/26 13:37:56
摘要:移相全桥ZVS变换器是中大功率DC/DC变换场合的理想拓扑之一,但在其输出整流二极管反向恢复时,整流桥产生寄生振荡,二极管上存在很高的尖峰电压。这将带来电路损耗,并影响整流桥的使用寿命。本文分析了振荡产生的原因,并介绍了抑制的方法。重点分析了一种原边加箝位二极管的缓冲电路形式,制做了一个5.5kW样机,并给出了对比实验结果。
叙词:寄生振荡;尖峰电压;箝位二极管
Abstract:There exists a problem of the Phase-shifted full-bridge zero-voltage-switching(PS-FB-ZVS) PWM converter, which is widely used at medium and high power levels, that the output rectifier diodes suffer the parasitic oscillation and voltage spike resulted by the reverse recovery of the rectifier diodes. In this paper, the reasons and restraining methods are discussed, and a novel ZVS converter is proposed which adopts two clamping diodes in the first side of transformer. The operation principle of the novel converter is analyzed and the experimental results of a 5.5kW prototype converter are also given.
Keyword:parasitic oscillation; voltage spike; clamping diodes
说明:本站会员正确输入用户名和密码进行登录系统后才能查看文章详细内容和参与评论。
--本文摘自《电源世界》,已被阅读5065次
免责声明:本文仅代表作者个人观点,与电源在线网无关。其原创性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不作任何保证或承诺,请读者仅作参考,并请自行核实相关内容。