多电平变频器无速度传感器直接转矩控制的研究
作者:孙伟 何礼高 上传时间:2009/4/11 10:26:51
摘要:在级联多电平直接转矩控制中,通过引入错时采样空间矢量调制法,采用PI调节与错时采样空间矢量调制,摒弃开关向量表与滞环比较器,可以克服传统直接转矩控制开关向量表复杂、波形质量差、转矩脉动大、开关频率不定等缺点。无速度传感器技术的使用可提高可靠性与降低成本。与其他多电平空间矢量算法相比,其功率单元使用均衡,执行效率高,易于实现,可保证无速度传感器直接转矩控制的实时性。通过仿真对这一方法进行了证明。
叙词:错时采样空间矢量调制 直接转矩控制 无速度传感器 级联多电平逆变器
Abstract:In the area of direct torque control (DTC) for cascade multilevel inverter, by introducing the sample-time-staggered space vector modulation (STS-SVM), adopting PI regulation and STS-SVM strategy, getting rid of the switching vector tables and hysteresis comparators, the disadvantages such as complex switching vector tables, low quality output waves, large torque ripple, and unfixed switching frequency are overcomed. The adopting of speed sensorless technology can increase the reliability and decrease the cost. Compared with other multilevel SVM algorithms, STS-SVM can use the power cells in equilibrium, be implemented easily and be performed efficiently. It can satisfy the real-time require of speed sensorless direct torque control. This method is proved by simulation.
Keyword:Sampe-time-staggered space vector modulation, Direct torque control, Speed sensorless, Cascade multilevel inverter
说明:本站会员正确输入用户名和密码进行登录系统后才能查看文章详细内容和参与评论。
--本文摘自《电源世界》,已被阅读2332次
免责声明:本文仅代表作者个人观点,与电源在线网无关。其原创性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不作任何保证或承诺,请读者仅作参考,并请自行核实相关内容。
投稿热线 :0755-82905460 邮箱 :news@cps800.com
关于本文的网友评论:
本文暂时还没有网友发表评论信息!