产品说明:
HB-DC电源测试负载箱应用于各类发电机及UPS电源的日常维护测试、工程验收、出厂检验测试。普遍存在并急需解决的问题:根据众多基层维护工作人员的最新调查反映,目前UPS设备维护工作中普遍存在的维护技术难题是。各类UPS设备的输出功率与带载能力的检测工作一直以来无法有效顺利进行,只有等到供电故障发生后才知道是发电机组性能出现问题了。
HB-DC电源测试负载箱可以精确测试各类发电机组及UPS设备的输出功率与带载能力。
Product Description:
The HB-DC ups power test load bank is applied into maintenance test, acceptance of works and delivery inspection of various power generators and UPS power supplies. the common and urgent problems are as follow: according to the latest survey from many grass-roots maintenance staffs, it showed the common technical problem during current maintenance work of UPS equipment is that the testing work of output power and load capability in various UPS equipments has been unable to effectively proceed smoothly, the problem is not found in the performance of generator set until the power failure occurred.
The HB-DC power test load box can test the output power and load capacity of various generator sets and UPS equipments accurately.
功能介绍:
1、新装UPS设备的工程验收时,检测UPS设备输出功率及蓄电池能否达到设计要求。
2、UPS设备日常维护例行检测,根据新颁发通信电源维护规程要求,每年要对UPS设备进行核对性放电试验。
4、功率、电压、电流、频率、等等重要参数的测试数据一目了然。
5、可设定恒功率放电值(无段式)
6、所有高效能电热元件均符合UL安全规格
7、具有风扇故障检测、过压、过流、漏电等保护功能。
8、可多部并联放电,以适应大电流放电的场合。
Features:
1. Used to test whether the output power of UPS equipments and batteries can reach the design requirements while launching project acceptance to the UPS equipments newly installed.
2. The UPS equipments should be in daily maintenance and routine testing, the checking discharge test should be implemented in UPS equipments each year according to the requirements in the maintenance regulations for communication power supply issued newly.
3. It can be clear of the test data of power, voltage, current, frequency, and other important parameters.
4. It is available to set the discharge value of constant power (the step-less).
5. All of high-performance heating elements are in line with UL safety standards.
6. It has the fault detection function for fan, the protective function in over-voltage, over-current, and leakage.
7. The discharge can be in multi-parallel connection to fit in the condition of the large current discharge.
应用领域:
检测电源、UPS设备、交流稳压器、逆变器、开关电源等通信交流设备的输出功率与带载能力。
产品名称 |
14V车载电源测试负载 |
24V直流电源测试负载 |
48V直流屏测试负载 |
220V直流系统蓄电池充放电负载 |
380V直流焊机测试负载 |
600V铁路客车电源测试负载 |
型号 |
HB-DC系列 |
负载箱主要技术指标 |
额定电压 |
直流 DC 14V |
直流 DC 24V |
直流 DC 48V |
直流 DC 220V |
直流 DC 380V |
直流 DC 600V |
额定功率 |
7KW |
12KW |
24KW |
22KW |
190KW |
600KW |
频率 |
NA |
NA |
NA |
NA |
NA |
NA |
负载性质 |
纯阻性 |
纯阻性 |
纯阻性 |
纯阻性 |
纯阻性 |
纯阻性 |
控制方式 |
直流断路器 |
直流断路器 |
直流断路器 |
直流断路器 |
直流接触器 |
直流接触器 |
电流分段 |
1A-500A |
1A-500A |
1A-500A |
1A-100A |
1A-500A |
1A-1000A |
电压精度 |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
0.5% |
电压分辨率 |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
调节精度 |
±5% |
±5% |
±5% |
±5% |
±5% |
±5% |
仪表显示 |
LED数字电流表、电压表(其他仪表可选配) |
LED数字电流表、电压表(其他仪表可选配) |
LED数字电流表、电压表(其他仪表可选配) |
LED数字电流表、电压表(其他仪表可选配) |
LED数字电流表、电压表(其他仪表可选配) |
LED数字电流表、电压表(其他仪表可选配) |
负载保护 |
过流保护、过压保护,高温报警,风机故障报警(可选配) |
过流保护、过压保护,高温报警,风机故障报警(可选配) |
过流保护、过压保护,高温报警,风机故障报警(可选配) |
过流保护、过压保护,高温报警,风机故障报警(可选配) |
过流保护、过压保护,高温报警,风机故障报警(可选配) |
过流保护、过压保护,高温报警,风机故障报警(可选配) |
散热方式 |
强制风冷 |
强制风冷 |
强制风冷 |
强制风冷 |
强制风冷 |
强制风冷 |
外形结构 |
650*430*700mm 框架结构,可移动 |
650*430*700mm 框架结构,可移动 |
850*580*700mm 框架结构,可移动 |
850*580*700mm 框架结构,可移动 |
1600*800*1000mm 框架结构,可移动 |
1800*1000*1500mm 框架结构,可移动 |
配选功能 |
电脑远程监控,RS485电脑通讯数据上传,报表打印 |
电脑远程监控,RS485电脑通讯数据上传,报表打印 |
电脑远程监控,RS485电脑通讯数据上传,报表打印 |
电脑远程监控,RS485电脑通讯数据上传,报表打印 |
电脑远程监控,RS485电脑通讯数据上传,报表打印 |
电脑远程监控,RS485电脑通讯数据上传,报表打印 |